Skip to content

ThresholdMonitoringEvents¤

Multi-level threshold monitoring with hysteresis for numeric signals.

Module: ts_shape.events.engineering.threshold_monitoring
Guide: Process Engineering


When to Use¤

Use for continuous monitoring of process limits. Multi-level thresholds (warning/alarm/critical) with hysteresis prevent chattering around limit boundaries. Ideal for real-time alerting pipelines and shift-level compliance reporting.


Quick Example¤

from ts_shape.events.engineering.threshold_monitoring import ThresholdMonitoringEvents

monitor = ThresholdMonitoringEvents(
    df=process_data,
    uuid="reactor_pressure_01"
)

# Define warning, alarm, and critical levels
levels = [
    {"name": "warning", "value": 85.0},
    {"name": "alarm", "value": 92.0},
    {"name": "critical", "value": 98.0},
]
exceedances = monitor.multi_level_threshold(levels, direction="above")

# Hysteresis-based alarm to avoid chattering
alarms = monitor.threshold_with_hysteresis(high=90.0, low=85.0)

# Track cumulative time above a limit per hour
time_above = monitor.time_above_threshold(threshold=85.0, window="1h")

Key Methods¤

Method Purpose Returns
multi_level_threshold(levels, direction='above') Multi-level threshold detection DataFrame of level exceedances
threshold_with_hysteresis(high, low) Alarm with hysteresis band DataFrame of alarm intervals
time_above_threshold(threshold, window='1h') Cumulative time above per window DataFrame with durations
threshold_exceedance_trend(threshold, window='1D') Exceedance trend over time DataFrame with daily trend

Tips & Notes¤

Always use hysteresis for alarms